Page 15 - raport symulacja
P. 15

Structural Analysis of Fan Section of Air Handling Unit KMW ZR 30                                                             15/22
   on Dynamic Load Defined by Seismic Spectrum OLKILUOTO 3

Table 2. Allowable stresses                             Allowable
                                                         stresses
              Component Yielding stress Safety factors
                   type MPa                                MPa

walls and         235                           1.5      k1 = 157
 frames           640                           1.5
 screws                                                  k2 = 427

The stresses in the frames and surfaces of membranes are of the order of several MPa’s
only, Fig. 16. Stresses in all critical points clearly satisfy the condition of strength,
Table 3.

Table 3. Equivalent stresses in membrane parts

Point no. Equivalent stress                     Allowable
                       MPa                      stresses

           61515       14.5                        MPa
           61516       14.48
           61514       11.7                       ≤ k1 = 157
           61517       11.5

Fig. 16. Equivalent stresses in membrane parts

                                                                                  University of Technology and Life Sciences
                                                                                  Faculty of Mechanical Engineering
                                                                                  Department of Computer Methods
   10   11   12   13   14   15   16   17   18   19   20